Part Number Hot Search : 
D15XB80 MCP6V06T BU608 70246 160CA 1608X7R HSU88 2N2219A
Product Description
Full Text Search
 

To Download SFPD-GB-E08-33-A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 parameter symbol min typical max unit optical power (sfpd-gb-xx-xx-a) p op 0 2 4 dbm optical power (sfpd-gb-exx-xx-a) p op 3 5 7 dbm average launch power (tx:off) p off - - -30 dbm extinction ratio er 8.2 - - db eye mask - - - ieee 802.3, sonet/sdh compliant optical jitter generation jgen(pk-pk) - - 0.07 ui optical rise time b t r - - 160 ps optical fall time b t f - 160 ps channel spacing ? f - 100 - ghz deviation from central frequency, eol 12 ghz spectral width (20db) ? - - 0.3 nm side mode suppression ratio smsr 30 - - db dispersion penalty at speci?ed distance c dp - - 2 db relative intensity noise rin - - -135 db/hz re?ection tolerance d rp -24 - - db transmitter speci?cations (optical) features ? available in all 100 ghz c-band wavelengths on the dwdm itu grid ? dwdm sfp msa compliant ? cold start up wavelength compliance ? low power dissipation <1.5w maximum ? -5oc to 70oc operating case temperature ? ieee 802.3ah compliant ? pluggable into existing standard sfp cages ? diagnostic performance monitoring of transmit power, receive power, laser bias, module temperature, laser temperature, apd bias voltage, tec current ? apd based receiver sensitivity of -28dbm at 1.25gb/s ? long reach 80km and 120km version available ? high tx output power (+5dbm) version available parameter symbol min. typical max. unit supply voltage v cc 3.135 3.3 3.465 v total current (bol) i cc - - 375 ma power supply noise rejection a psr 100 - - mv p-p operating case temperature t op -5 - 70 oc storage temperature t st -40 - 85 oc data rate multirate mr 100 - 2700 mbps general operation a) 20hz to 155mhz b) 20%-80% values c) measured at ber of 10 -12 , 1.25gb/s , at eye center. for sfpd-gb-08-xx/exx-a, measured at 80km (1600ps/nm); for sfpd-gb-12-xx/exx-a, measured at 120km (2400ps/ nm). d) 2db degradation of receiver sensitivity
2 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 parameter symbol min typical max unit input differential impedence r in 80 100 120 pecl single-ended data input swing v in,p-p 250 - 1200 mv txfault_fault v fault 2 - v cc v txfault_normal v normal v ee - v ee +0.5 v txdisable_disable v d 2 - v cc v txdisable_enable v en v ee - v ee +0.8 v transmitter speci?cations (electrical) parameter symbol min typical max unit receive power low e r sens,low - -30 -28 dbm receive power high r sens,high -6 - - dbm damage threshold for receiver p in,damage 4 - - dbm wavelength 1528 - 1564 nm maximum re?ectance of receiver rx_r - - -27 db los assert -38 - - dbm los de-assert - - -28 dbm los hysteresis 0.5 - - db receiver speci?cations (optical) e) at 10 -12 ber, 1.25g b/s, 1310nm to 1610nm received waveleng th. at wavelength ranges of 1260 nm to 1310nm and 1610nm to 1620nm, maxim um sensitivity penalty is 1db parameter symbol min typical max unit single-ended data output v out, p-p 185 - 800 mv data output rise time t r - - 175 ps data output fall time t f - - 175 ps receiver speci?cations (electrical) parameter symbol min typical max unit tx disable negate time t_on - - 20 ms tx disable assert time t_off - - 20 ms time to initialize after reset of tx_fault/int in normal operation t_init - - 300 ms start-up time t_startup - - 90 secs tx fault/int assert time t_fault - - 50 ms tx disable to reset t_reset 10 - - s los assert time t_loss_on - - 100 s los de-assert time t_loss_off - - 100 s serial id clock rate f_serial_clock - - 100 khz rx_los voltage (high) 2 - - v rx_los voltage (low) - - 0.8 v los output voltage-fault v los fault 2 - v cc v los output voltage-normal v los normal v ee - v ee +0.55 v mod_def (0:2)-high v h 2 - v cc v mod_def (0:2)-low v l v ee - v ee +0.5 v timing and electrical
3 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 wavelength ordering itu channel/product code frequency (thz) wavelength (nm) itu channel/product code frequency (thz) wavelength (nm) 15 191.5 1565.495 39 193.9 1546.119 16 191.6 1564.678 40 194.0 1545.322 17 191.7 1563.863 41 194.1 1544.526 18 191.8 1563.047 42 194.2 1543.730 19 191.9 1562.233 43 194.3 1542.936 20 192.0 1561.419 44 194.4 1542.142 21 192.1 1560.606 45 194.5 1541.349 22 192.2 1559.794 46 194.6 1540.557 23 192.3 1558.983 47 194.7 1539.766 24 192.4 1558.173 48 194.8 1538.976 25 192.5 1557.363 49 194.9 1538.186 26 192.6 1556.555 50 195.0 1537.397 27 192.7 1555.747 51 195.1 1536.609 28 192.8 1554.940 52 195.2 1535.822 29 192.9 1554.134 53 195.3 1535.036 30 193.0 1553.329 54 195.4 1534.250 31 193.1 1552.524 55 195.5 1533.465 32 193.2 1551.721 56 195.6 1532.681 33 193.3 1550.918 57 195.7 1531.898 34 193.4 1550.116 58 195.8 1531.116 35 193.5 1549.315 59 195.9 1530.334 36 193.6 1548.515 60 196.0 1529.553 37 193.7 1547.715 61 196.1 1528.773 38 193.8 1546.917 c wavelength guide sfpd-gb-xx/exx-xx-a see table below for xx values
4 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 name of field description of field address hex ascii vendor name sfp vendor name(ascii) 20 4c l 21 55 u 22 4d m 23 49 i 24 4e n 25 45 e 26 4e n 27 54 t 28 4f o 29 49 i 30 43 c vendor oui ieee vendor oui code for luminentoic inc. 37 00 38 06 39 b5 vendor p/n part number in ascii, e.g. sfpd-gb-xx-xx-a 40 53 s 41 46 f 42 50 p 43 44 d 44 47 g 45 42 b 46 x x 47 x x 48 x x 49 x x 50 41 a eeprom serial id parameter range accuracy unit temperature -5 to 70 3 o c voltage 0 to v cc 0.1 v bias current 0 to 120 5 ma tx power 0 to 5 2 dbm rx power -32 to -9 2 dbm tec current -1200 to 1200 60 ma tec temperature f 20 to 70 0.25 oc diagnostics f) relative accuracy.absolute accuracy is +/-3 oc
5 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 pin function notes 1 v ee t tx ground 2 tx_fault/int open collector 3 tx_disable internally pulled high 4 mod_def2 serial data input 5 mod_def1 serial clock input 6 mod_def0 internally grounded 7 nc not connected 8 los open collector 9 v ee r rx ground 10 v ee r rx ground 11 v ee r rx ground 12 rxd- rx data negative 13 rxd+ rx data positive 14 v ee r rx ground 15 v cc r rx power 16 v cc t tx power 17 v ee t tx ground 18 txd+ tx data positive 19 txd- tx data negative 20 v ee t tx ground
6 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 luminentoic.com con?dential and proprietary lumnds728-jun122006 rev 0.7 outline drawing suggested transceiver interface s e r d e s 1 0 0 ? r e c e i v e r a m p l i f i e r r d + r d - . 0 1 f . 0 1 f m o d _ d e f 2 m o d _ d e f 1 m o d _ d e f 0 v c c r 1 r 1 r 1 r 1 = 4 . 7 t o 1 0 ? e e p r o m r x _ l o s r 1 l a s e r d r i v e r . 0 1 f . 0 1 f 1 0 0 ? t d + t d - t x _ f a u l t t x _ d i s a b l e p r o t o c o l i c r 1 v e e t . 0 1 f 0 . 1 f 1 0 f 1 h v c c l u m i n e n t o i c v e e r 0 . 1 f 1 0 f 1 h v c c r t x _ d i s a b l e t x _ f a u l t r x _ l o s v c c t 1 0 k ?
20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 7 gigabit ethernet dwdm sfp transceiver preliminary sfpd-gb-xx-xx-a luminentoic.com con? dential and proprietary important notice! all information contained in this document is subject to change without notice, at luminentoic s sole and absolute discretion. luminentoic warrants performance of its products to current speci? cations only in accordance with the companys standard one-year warranty; however, speci? cations designated as preliminary are given to describe components only, and luminentoic expressly disclaims any and all warranties for said products, including express, implied, and statutory warran- ties, warranties of merchantability, ? tness for a particular purpose, and non-infringement of proprietary rights. please refer to the companys terms and conditions of sale for further warranty information. luminentoic assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. no license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and luminentoic makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. products described in this docu- ment are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. luminentoic customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify luminentoic for any damages resulting from such use or sale. the information contained in this document is provided on an as is basis. customer agrees that luminentoic is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. customer must contact luminentoic to obtain the latest version of this publication to verify , before placing any order, that the information contained herein is current. ? luminentoic, inc. 2003 all rights reserved handling precautions: this device is susceptible to damage as a result of electrostatic discharge (esd). a static free environment is highly recommended. follow guidelines according to proper esd procedures. laser safety: radiation emitted by laser devices can be dangerous to human eyes. avoid eye exposure to direct or indirect radiation. warnings: legal notes: lumnds728-jun122006 rev 0.7 ordering information availab le options: sfp d -gb-08-xx-a sfpd-gb-e08-xx- a sfp d -gb-12-xx-a sfpd-gb-e12-xx-a part numbering de? nition: s f p d - g b - reach - itu channel - revision - customization sfpd = dwdm sfp gb = gigabit ethernet sfpd = dwdm sfp xx = 15 to 6 1 x = design revision 08 = 80km, 12 = 120km exx = high power (+3 to +7dbm) xx = customization


▲Up To Search▲   

 
Price & Availability of SFPD-GB-E08-33-A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X